alice 2020-07-31 21:06:12 +00:00
parent 97213af37b
commit 209782a581

@ -9,38 +9,36 @@ A project to add solar power to the VW T3 Joker
# Conditions # Conditions
Energy sources **Energy sources**
- Starter battery - Starter battery
- Leasure battery - Leasure battery
- Engine - Engine
- 220 input - 220 input
**Energy consumtion**
Energy consumtion
- Pentry fuse 16A - Pentry fuse 16A
- Fridge 85W - Fridge 85W
- Indicator display (oklart men extremt lite. Letar efter källa) - Indicator display (oklart men extremt lite. Letar efter källa)
- Waterpump (pentry)(12V 2A => 12*2=24W) - Waterpump (pentry)(12V 2A => 12*2=24W)
- Fridge fan (0,6W) - Fridge fan (0,6W)
Other stuff **Other stuff**
- Unsure about the fuse directly at the battery but should use one 8A - Unsure about the fuse directly at the battery but should use one 8A
- Battery charger type LG 20 - Battery charger type LG 20
# The panel # The panel
**Specs**
- 110 W - 110 W
- 18V rated voltage - 18V rated voltage
-
-
# The MPPT # The MPPT
Specs **Specs**
- ESP32 - ESP32
- Diod preventing the protective diods in the box at the back of the panel breaks if the panel is connected with the wrong polarityand preventing old/bad panels to discharge the battery when it is dark. Stuges test shows that this diod will be what limits the effect/power the chager can handle. With a load at 6A he measured 113 °C on the outside of the diod. The it is close to the max temperature (150 °C) on the inside. At a load at 6A he measured 100W in, the used panel in this project is 110W. This is working since the panel never produces 100%. But it is close to the limit if the chager is loaded at 6A. - Diod preventing the protective diods in the box at the back of the panel breaks if the panel is connected with the wrong polarityand preventing old/bad panels to discharge the battery when it is dark. Stuges test shows that this diod will be what limits the effect/power the chager can handle. With a load at 6A he measured 113 °C on the outside of the diod. The it is close to the max temperature (150 °C) on the inside. At a load at 6A he measured 100W in, the used panel in this project is 110W. This is working since the panel never produces 100%. But it is close to the limit if the chager is loaded at 6A.
Testprotocols **Testprotocols & measurements**
- Stuge 10 July (Stuge)
Stuge 10 July (Stuge)
``` ```
OpenMPPT OpenMPPT
@ -81,7 +79,7 @@ In 20V 4.84A Out 6A 14.15V 84.88W D6 Tterm=104.4°C N4
10. Jul., 09:26 10. Jul., 09:26
``` ```
Elektra resources and similar **Elektra resources and similar**
- https://github.com/ISEMS/ISEMS-ESP32 - https://github.com/ISEMS/ISEMS-ESP32
- https://media.ccc.de/v/36c3-oio-166-ff-esp32-openmppt-new-freifunk-isems-mppt-solar-controller-with-integrated-wifi - https://media.ccc.de/v/36c3-oio-166-ff-esp32-openmppt-new-freifunk-isems-mppt-solar-controller-with-integrated-wifi
- https://www.isems.de/ - https://www.isems.de/
@ -89,10 +87,9 @@ Elektra resources and similar
- https://media.ccc.de/v/35c3oio-63-independent-solar-energy-mesh-system - https://media.ccc.de/v/35c3oio-63-independent-solar-energy-mesh-system
# The current setup # The current setup
Cables & connetors **Cables & connetors**
- Red/Black connectors (Powerpole 75) not water proof - Red/Black connectors (Powerpole 75) not water proof
- Panel connectors (MC4/H4) cannot hang unconnected in moist! - Panel connectors (MC4/H4) cannot hang unconnected in moist!
# Dictionary # Dictionary
Rated voltage - Nominell spänning / märkspänning Rated voltage - Nominell spänning / märkspänning
Alternator - Lichtmachine - Generator Alternator - Lichtmachine - Generator